Availability

This feature is available starting with v4.5.0 of the power apps.


Often, during the development of an integration or a special customization, people get stuck because of the lack of context. Questions appear: which user clicked the button for the next status? Did the manager approve this item? What was the result of the calculation in the previous step? The traditional way of dealing with such questions was to create additional custom fields to keep that data, usually hidden from users (so excluded from the screens schemes), effectively adding bloat to Jira and ultimately worsening indexing - and general - performance. To help you answer these kinds of questions, Simple Issue Language™ (or SIL™) acquired, starting with version 4.5.0 of the SIL Engine™, a new feature, called persistent variables.

So, what's a persistent variable? In short, in an issue context, a persistent variable is a value inherently linked to the issue. Think of it as an extension of the issue fields, or - making another analogy - an additional custom field, but internal to SIL™. Outside the issue context, the persistent variable becomes a global variable, accessible from all scripts. It is better to see some usage, so you can get a better grasp on what it means and how it can simplify your SIL™ usage throughout your Jira integration.

Usage in an issue context

Persistent variables are introduced via the persistent keyword. In order to save space, we do not allow persistent and constant modifiers to be used on the same variable, so you can't have both. A persistent variable is always modifiable.

Let's install the following post function on an easy executable action (like "Start Progress" on the default simplified workflow of Jira), and execute the transition a number of times (a normal Start-Stop progress cycle, in this example, on the same issue).

A postfunction with persistent variables
persistent number counter = 1; 
persistent boolean flag = false; 
 
description += "\n" + counter + "(" + flag + ")"; 
 
flag = !flag; 
 
counter ++;

The above example adds some text to the description of an issue, but unlike the version without the persistent keyword, the appended text will be something like:

1(false)
2(true)
3(false)
4(true)

So what's happening here? The truth is that the initialization of the variable happens only once. Subsequent executions will find the persistent variable initialized, will load that particular value, and start from there. The flag will be flipped, and the counter will be incremented with each executed transition on that issue.

The persistent variable is linked to the issue so that If you move to another issue and execute the same post function multiple times, you will get a similar output. The first line of the output will still be 1(false) followed by 2(true) and so on.

Examples

Let's suppose that we have a SIL™ listener and we'd like to use that counter variable. You can simply access it in your listener like in the following example:

A listener code
persistent number counter;
persistent boolean flag = true; //initialization is ignored if the previous script was already executed!
//.............
/// use it in the listener like a normal variable:
counter--;

Note that we didn't put any initializer. If the variable is already initialized, the initializer is simply not executed at all, no matter the construct. While such behavior belongs to the logic of the persistent variable, we recommend that you use the same initializer every time so that you won't start with different values.

Script 1
persistent number counter = 1;
persistent boolean flag = true;
...
Script 2
persistent number counter = 1;
persistent boolean flag = true;
...
Script 3
persistent number counter = 1;
persistent boolean flag = true;
...

NOT Recommended

Script 1
persistent number counter = 1;
persistent boolean flag = true;
...
Script 2
persistent number counter = 100;
persistent boolean flag = false;
...
Script 3
persistent number counter = 7;
persistent boolean flag = true;
...


In conclusion:

  1. The persistent variable is linked to the current issue from the context.
  2. Persistent variables are only initialized once. Initialization of a persistent variable will be ignored if that variable was already initialized from a previous execution within a particular context.
  3. A persistent variable is a variable whose value survives the script, making it available in many other scripts under the same name.

Usage outside the issue context

The usage outside the issue context is very similar. However, due to the nature of the persistent keyword, the variable, in this case, becomes a global variable. Take for instance the following script, run from the SIL™ Runner gadget:

persistent number counter = 1; 
persistent boolean flag = false; 
 
TEST-1.description += "\n" + counter + "(" + flag + ")"; 
 
flag = !flag; 
 
counter ++;


The counter variable will be incremented as before (starting from 1) and the text above will be re-appended to the issue 'TEST-1'. However, if we change just the issue, say to 'TEST-2', the counter will retain its previous value, incrementing from the value it stopped when you run the above for the TEST-1 issue. Just try it!

Persistent variables are effectively global if used outside of the issue context.

Helper routines

There are two helper routines available to ease your work with persistent variables. These routines allow you to set or retrieve the value of a persistent variable from a script that is not in the context of the issue or just to retrieve a global variable:

Routines

  • Page:
    setPersistentVar (Simple Issue Language™) — Sets the persistent var, as a string
  • Page:
    getPersistentVar (Simple Issue Language™) — Gets the persistent var, as a string

Values are treated as strings. For the above example:

string globalCounterVar = getPersistentVar("counter");
number test_one_counter = getPersistentVar("TEST-1", "counter"); //notice the implicit cast! values are treated like strings, though!

Notes

  • Although useful, persistent variables come with a small performance penalty. Don't overuse them!
  • There's no way to delete a persistent var (other than direct SQL) at the moment. Think hard if you really need them.

More Examples

Approvals

Let's say you want to create an approval process where a manager must approve a ticket before it can be worked on. This can be accomplished by creating a workflow transition, called "Approve",  that leads back to the original step. Only a manager can see this transition button and when they transition the ticket it will be marked as approved. To do this we would need a couple scripts on this Approval transition:

Condition Script:
//This condition script hides the transition if the user is not a manager or if the issue has already been approved
persistent boolean approved = false;

if(approved == true or userInGroup("managers", currentUser() == false) {
	return false;
}
Post Function Script:
//This post function script marks the issue as approved using a persistant variable
persistent boolean approved = true;

This validator script would go on the "Start Progress" transition, for example.

Validator Script:
//This validator script prevents the user from starting work on the issue until it has been approved
persistent boolean approved;
string errMsg = "You can not perform this action because this ticket has not been approved by a manager";

if(approved != true) {
	return false, "", errMsg;
}

Stored Passwords

It is not a good practice to have passwords stored in your script. One way to achieve this is to store the password in a persistent variable. To create the password as global variable run the following script once through the SIL Runner Gadget or the SIL Scheduler:

persistent string apiPassword = "password132";

Then, in a script where the password is required, you can retrieve the value using the getPersistentVar() routine.

HttpRequest request;
HttpHeader authHeader = httpBasicAuthHeader("admin", getPersistentVar("apiPassword"));
request.headers += authHeader;
...

File Path

If you commonly use routines that require the full file path of a file you can save yourself a step by storing the root file path as a persistent variable. To create the password as global variable run the following script once through the SIL Runner Gadget or the SIL Scheduler:

persistent string rootPath = "/var/atlassian/application-data/jira/";

Then, in your script, you can retrieve the value.

string path = getPersistentVar("apiPassword") + "silprograms/calls/test.sil";