Persistent Variables Outside the Issue Context

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Next »

The usage outside the issue context is very similar. However, due to the nature of the persistent keyword, the variable, in this case, becomes a global variable. Take for instance the following script, run from the SIL™ Runner gadget:

persistent number counter = 1; 
persistent boolean flag = false; 
 
TEST-1.description += "\n" + counter + "(" + flag + ")"; 
 
flag = !flag; 
 
counter ++;


The counter variable will be incremented as before (starting from 1) and the text above will be re-appended to the issue 'TEST-1'. However, if we change just the issue, say to 'TEST-2', the counter will retain its previous value, incrementing from the value it stopped when you run the above for the TEST-1 issue. Just try it!

Persistent variables are effectively global if used outside of the issue context.

Example Use Cases

Stored Passwords

It is not a good practice to have passwords stored in your script. One way to achieve this is to store the password in a persistent variable. To create the password as global variable run the following script once through the SIL Runner Gadget or the SIL Scheduler:

persistent string apiPassword = "password132";

Then, in a script where the password is required, you can retrieve the value using the getPersistentVar() function.

HttpRequest request;
HttpHeader authHeader = httpBasicAuthHeader("admin", getPersistentVar("apiPassword"));
request.headers += authHeader;
...

File Path

If you commonly use functions that require the full file path of a file you can save yourself a step by storing the root file path as a persistent variable. To create the password as global variable run the following script once through the SIL Runner Gadget or the SIL Scheduler:

persistent string rootPath = "/var/atlassian/application-data/jira/";

Then, in your script, you can retrieve the value.

string path = getPersistentVar("rootPath") + "silprograms/calls/test.sil";